Search OsseoTECH
OsseoTECH - Chronicling Osseointegration Developments


Weekly Update                

Features
Welcome to OsseoTECH, a site devoted to chronicling osseointegration developments Please send suggestions for features.


Sponsors
Links
CDE-Directory - A Comprehensive Guide to Continuing Dental Education
OsseoNews - The World of Implant Dentistry Online
PalmDMD - PDA's in clinical dentistry
Medgadget - Emerging Medical Technologies
PalmDDS - PDA's in clinical dentistry
CurrentJournals - Keeping you updated Automatically - Keywords, Journals, Authors delivered weekly in an easy to read PDF format
Page: << | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 | 20 | 21 | >>
Osseous Technologies of America`s Balloon Sinus Lifter 

Posted by:Editor on Monday May 8th, 2006  

OTA`s new balloon sinus lifter allows for less traumatic hydraulic sinus lifts (internal and lateral approach) by reducing the risk of membrane tears. The micro-mini balloon inflates to 1.9mm with saline administered via a 5cc syringe. The gentle pressure on the membrane expands the sinus graft space gently without any sharp instruments.

More

Movie

0 Comments:

E-Mail This     Topic: Implant Placement Guides

Mectron Piezoelectric Bone Surgery System 

Posted by:Editor on Tuesday May 2nd, 2006  

Mectron`s piezon-electric surgery system can be used for osteotomies and osteoplasty in implantology. Additionally it can be used in periodontal, endodontic and surgical orthodontics. It`s selective cutting action allows for mimimal soft tissue damage, especially useful for opening sinus windows during lateral sinus lift procedures. This unit comes with an array of handpiece tips designed for an array of surgical procedures.

More

1 Comments:   .. This is truly the state-of-the-art and works very ..

E-Mail This     Topic: Implant Placement Guides

DenX`s IGI Implantology navigation system wins 2006 Medical Design Excellence Award 

Posted by:Editor on Friday April 28th, 2006  

DenX`s innovative CT-image driven implant planning and placement system, `IGI`, was recently honoured with a Medical Design Excellence Award. IGI allows a virtual implant to be placed on the CT image with the assistance of advanced planning tools. During the surgical procedure, the clinician guides the implant to the precise location, angle and depth required according to the plan. Real-time localization feedback assisted by audio and visual media allows the clinician to monitor the success of the procedure and avoid critical mistakes at all times. * This is an interesting design competitor to Tactile Tech`s ILS System as previously reported on osseotech.com

More

0 Comments:

E-Mail This     Topic: Software

MIS Ceramic Composite Implant Drills 

Posted by:Editor on Tuesday April 25th, 2006  

MIS has introduced a ceramic composite (Zirconium / Yttrium / Aluminium) drills in 2.0 mm, 2.1 mm and 2.8 mm diameter. They reportedly feature reduced vibration and smoother operation. One important property that Zirconium drills claim over stainless-steel drills is that they maintain their sharp edge for an extended period.

More

Brochure

1 Comments:   .. I have used the 2.0 mm MIS pilot drill for about 1 ..

E-Mail This     Topic: Drill Design

Straumann`s Peek/Titanium Composite Implant? - US Patent Pending 

Posted by:Editor on Tuesday April 25th, 2006  

Straumann has filed a US patent application for a Peek/Titanium composite one-piece Implant. This implant design features an outer titanium shell (label 1 and 2) and an inner core made of PEEK (label 3 and 4). This designs claims the aesthetic advantage of the white-coloured PEEK at the collar and abutment with the proven osseointegration properties of titanium. This is an interesting design response to the number of zirconium collar (TBR Group) and all zirconium implant (Z-Systems) designs.

More

Patent Application

0 Comments:

E-Mail This     Topic: Patent

Thommen Medical`s SPI MONO Torque Ratchet 

Posted by:Editor on Monday April 24th, 2006  

Thommen Medical has introduced their SPI MONO torque ratchet. It is manufactured from a solid billet of titanium. It has a torque range of 10Ncm to 35Ncm in 5 Ncm increments. The one-piece construction simplifies regular maintenance as there are no parts to disassemble for cleaning and no lubrication is required.

More

0 Comments:

E-Mail This     Topic: Implant Placement Guides

Straumann`s New Asymmetrical Implant? - US Patent Pending 

Posted by:Editor on Saturday April 22nd, 2006  

Straumann has filed a US patent application for a root-form implant with an asymmetrical shoulder. It appears similar to their current TE implant design, with the addition of a sloping shoulder configuration higher on the palatal side and lower on the facial side. This may be their design response to NobelBiocare`s Nobel Perfect implant originally patented by Dr. Wohrle.

More

US Patent Application

2 Comments:   .. Unfortunately, the link was not to the correct pat ..

E-Mail This     Topic: Patent

Nobel Biocare`s Groovy Implant Surface 

Posted by:Editor on Thursday April 20th, 2006  

Nobel Biocare has introduced an improvement to their Ti-Unite Surface. By placing micro grooves on the surface they claim to increase the implant stability by up to 30% thereby allowing for more rapid bone formation. This surface improvement takes a mechanical approach to increase Bone-to-Implant Contact as opposed to the chemical surface modification`s introduced by Astra (Osseospeed) and Straumann (SLAtive), their main competitors.

More

0 Comments:

E-Mail This     Topic: Implant Surface

NSK`s Fiber-optic Implant Handpiece and Motor System 

Posted by:Editor on Tuesday April 18th, 2006  

NSK has introduced several improved features to their implantology handpiece and motor system. The `Surgic XT Plus` features a fiber-optic handpiece to illuminate the osteotomy site and a torque calibration feature to ensure precise speed and torque during surgery.

More

0 Comments:

E-Mail This     Topic: Software

Z-System`s All Zirconium Implants and Surgical Instruments 

Posted by:Editor on Monday April 17th, 2006  

Z-Systems has introduced a completely metal-free implant and set of surgical instruments for placement of these implants made from 95% Ziconium dioxide and 5% Yttrium tri-oxide. Zirconium is one of five metals shown to support osseointegration (the others are: Titanium, Niobium, Tantalum and Platinum). This new approach has been certified for use in Germany, but FDA clearance for use in the United States is planned. A few animal and human based studies suggest that the bone-to-implant contact percentages (a measure of the degree of osseointegration) are similar to those achieved with titanium-based implants.

More

1 Comments:   .. Implantodontista, Brasil --- Solicito pra avaliaçã ..

E-Mail This     Topic: Implant Placement Guides

Page: << | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 | 20 | 21 | >>

Click here to see all news in one page.

 

(c) 2005-2008 Boabab Publishing Inc.

     Terms of Use     |     Privacy Notice     |     Advertise with us

All trademarks are properties of their respective holders.